ACCURATE MACHINE TOOL SVC, INC. 770-995-0461
www.amtsinc.com
SERVO DYNAMIC SET-UP PROCEDURE
MILLS USING WESTAMP or SERVO DYNAMICS
DIRECT REPLACEMENT OF -006 WESTAMPS
WHEN PLUGGING THE J1 CONNECTOR ONTO THE SERVO DYNAMICS BOARD, ENSURE THE J1 CONNECTOR PLUGS INTO PIN 1 ON J1 CONNECTOR OF THE NEW BRD.THE J2 CONNECTOR IS NOT USED ALSO NOTE THE PINS 12,13,15 ARE NOT USED ON THE J1 CONNECTOR.
PRESETS( For simple tune up, set the TAC then skip to POWER UP SETTINGS)
USING AN OHM METER, BETWEEN STATED POINTS, MAKE THESE PRESET ADJUSTMENTS PRIOR TO INSTALLING THE BOARD. FOR EXISTING BOARDS PROCEED TO POWER UP SETTINGS.
ADJUST:
AUX POT: FULL CCW
SIG POT: TP3 TO TP1 = 1.7K OHM ON B AND 7.4K OHM ON BX.
TAC POT: FULL CW
*CMP POT: FULL CW THEN CCW 5 TURNS
*NOTE: START WITH POT FULL CW AND TURN CCW FOR DESIRED READING.
CL POT: FULL CWRMS POT: DO NOT ADJUSTPOWER UP SETTINGS
Copyright © 1996 Accurate Machine Tool Service, Inc.
1. ON SERVO CONTROL BRD(Not the Servo amps), CONNECTORS J2(X), J3(Y), AND J4(Z), CONNECT METER TO PINS 8 AND 9 FOR AXIS TO BE ADJUSTED. MAKE SURE TAC IS FULL CW.
2: POWER SERVOS UP, ADJUST SIG TO ACHIEVE .9 VDC B SERIES (.000") .65 VDC BX SERIES (.0000") OF DAC AT 25 IPM IN EITHER DIRECTION. IF AN IMBALANCE OF VOLTAGE OCCURS, ADJUST BAL TO GET BOTH DIRECTIONAL VOLTAGES WITHIN .050 VDC OF EACH OTHER.
3: NOW ZERO AXIS AND FINE TUNE BAL POT TO ACHIEVE CRT READINGS OF .000 OR .0000 WITHOUT FLICKERING.